Individual packaging:
1
With a barcode for retail sale
Bulk packaginig: 4
Operating range | max. 3,2 m³/h |
Lifting height | max. 6 m |
Media | water, glycol 50% |
Application | Clear liquid, free of solids, fibrous or mineral oily substances, non-viscous, chemically neutral, non-corrosive and non-explosive, with Similar to water, pumping a fluid with a viscosity pumping a fluid with a viscosity significantly higher than that of water will result in a significant deterioration pump may not function properly, The pump can be operated with glycol up to 50% concentration, in The pump may be operated with up to 50% glycol, in such cases the pump will operate with a reduced capacity. |
Liquid temperature | +2°C – +110°C for water |
-30°C – +110°C for a 50% glycol solution | |
Ambient temperature | 0°C – +70°C for water; RH <95% |
-30°C – +70°C for a 50% glycol solution; RH <95% | |
Maximum pressure | 10 bar |
Minimal inlet pressure depending on the liquid temperature |
0,05 bar up to 75°C |
0,5 bar up to 90°C | |
1,08 bar up to 110°C | |
Protection class | IP44 |
Insulation class | H |
Energy Efficiency Index | ≤0.20 |
Installation | with the shaft in a horizontal position |
Operating modes | AUTO |
HS – constant speed curves | |
BL – proportional pressure curves | |
HD – constant pressure curves | |
PWM – external input signal control (pulse width modulation) | |
Voltage | ~230 V (-6% – +10%), 50/60 Hz |
Power consumption | 5 – 25 W; 0,04 – 0,25 A |
Connection spacing | 180 mm |
Connection | G1 1/2 |
Included | flat gaskets (2 pcs.), 100 cm power cable |